It 's recommended that you inspect and test your fire sprinkler system every six months.
HOUSE FIRE SPRINKLER SYSTEM DESIGN FREE
Most contractors give free estimates for replacing sprinkler heads - be sure to get several in order to get a competitive price. Replacing your sprinkler heads is the best way to ensure that your system will function properly in the event of a fire.Īfter reviewing this information, please contact a licensed C-16 fire protection contractor and explain what you need done. What to Do if You Have Omega Sprinkler HeadsĪs a homeowner or occupant, you no doubt want to protect yourself and make sure that your vital life safety system is in proper working order. Because removing sprinkler heads takes special tools and knowledge, it is recommended that you contact a licensed sprinkler contractor. The model number can also be found on the body of the sprinkler head itself. You can also visually inspect your sprinkler heads and note the model number on the deflector, which is the piece of metal that is visible by looking at the sprinkler head from bottom. However, other models may look similar, so you should verify that the model is indeed a Central Omega sprinkler. The Central Omega sprinkler can be distinguished from most other fire sprinklers because of its three discs that protrude from the bottom.
HOUSE FIRE SPRINKLER SYSTEM DESIGN HOW TO
How to Know if You Have Omega Sprinkler Heads In some cases, these sprinkler heads were directly above a fire and still failed to operate. This in turn prevents a plug in the sprinkler head from being pushed out and allowing water to spray out. Why Omega Sprinkler Heads Are DefectiveĬentral Omega heads are one of several models of sprinkler heads in which the design includes a rubber O-ring seal that has been shown to degrade over time. View the letter online in English (PDF) or en Español (PDF). The Fontana Fire District recently sent out a letter on October 19, 2009, notifying all residents who may not be aware of this issue. As of 2009, there have been several such failures documented within the City of Fontana, indicating that there are potentially many of these Omega sprinkler heads in homes just like yours. The recall was announced after receiving reports of Omega sprinklers not functioning in several fires, resulting in millions of dollars in damages as well as injuries. On October 14, 1998, the U.S Consumer Product Safety Commission (CPSC) and Central Sprinkler announced a nationwide recall of approximately 8.4 million Omega brand fire sprinklers manufactured since 1982. The City of Fontana has required fire sprinklers in residential homes since 1987.